DEXAPLAN BA 611 - 08-2007 Información técnica Pagina 1

Busca en linea o descarga Información técnica para Los detectores de movimiento DEXAPLAN BA 611 - 08-2007. DEXAPLAN BA 611 - 08-2007 Technical information Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Dexaplan GmbH
Paul-Böhringer-Str. 3 ·
D-74229 Oedheim (Germany)
Information last updated: 08/2007
Ident.-No.: 08-2007-BA-611-GB/IE/CY
Vista de pagina 0
1 2 3 4 5 6 ... 13 14

Indice de contenidos

Pagina 1 - D-74229 Oedheim (Germany)

Dexaplan GmbH Paul-Böhringer-Str. 3 · D-74229 Oedheim (Germany)Information last updated: 08/2007Ident.-No.: 08-2007-BA-611-GB/IE/CY

Pagina 2 - TELEPHONE DIALLER

8 GB/IE/CYPress the OK key y฀฀ Wait 10 seconds until the device automatically quits the settings mode.Switching automatic dialling on / off

Pagina 3 - 2GB/IE/CY

9GB/IE/CY2. Positioning:You can position the alarm unit upright or lying down. If the surface is very smooth it is recommended that you place the devi

Pagina 4

10 GB/IE/CY฀ As determined by the automatic dialling function (factory setting: dialling function switched on) and the set number of dialling proces

Pagina 5 - Introduction

11GB/IE/CYSummary of the soundsSound MeaningThree pips The exit delay is activated, the arming of the alarm and emer-gency telephone dialler will be a

Pagina 6 - Disposal / Information

12 GB/IE/CYRectifying faultsFault Cause RemedyMotion detector detects motion without apparent reason.Pets, air move-ments, direct light, etc.Change th

Pagina 7 - Introduction/ Safety advice

L 16ALARM AND EMERGENCY TELEPHONE DIALLERBA 611ALARM AND EMERGENCY TELEPHONE DIALLEROperation and Safety Notes

Pagina 8 - Power supply

2GB/IE/CYIntroductionProper use... Page 4Included items ...

Pagina 9

3AQWERTaTYUIC{}qwertyuioDp[]BPOGF:a s dHIL M N100°6 m6 mca.40°ca. 4 mm27 mmfDEFGHL KA180°max. 90°K22 mmSJ

Pagina 10 - ฀฀฀

4 GB/IE/CYIntroductionPlease read carefully and completely through these ope-rating instructions and fold out page 3, the page with the illustrations.

Pagina 11

Disposal Dispose of packaging materials, used batteries and worn out devices at a local authority approved disposal facility.In accordance with Europe

Pagina 12

5GB/IE/CYTechnical informationAlarm unit BA 611 Operating voltage: 9V DC Current input:130mA (alarm), < 5mA (standby)Power supply: From the sup

Pagina 13

6 GB/IE/CY฀฀฀฀฀฀฀฀฀฀฀฀฀฀฀฀D Attention!฀฀ ฀฀฀฀฀฀฀฀

Pagina 14 - Cleaning

7GB/IE/CYMains adapter: Connect the mains adapter I to the mains adapter connection socket [ (9V). Connect the mains adapter to a suitable mains o